The Edge box
The Edge box sits beside your machines, reads their controllers and sends the values to Kaynan Nexus.
Quick-start card, English and Turkish, to print and put in the box.
Ports
| Port | For |
|---|---|
| 24V | Power, 9 to 36 V DC (the green plug) |
| ETH0 | The internet: your factory network or a router |
| ETH1 | The PLC network |
| Wi-Fi | The internet, when there is no cable for ETH0 |
Your factory network and the PLC network must be different ranges, for example 192.168.0.x and 192.168.1.x.
The label
Each box has a label with:
- Setup Wi-Fi and its password
- Claim code, like
ABCDE-23456
Keep the claim code private until the box is claimed. Anyone with an account and the code could claim it.
1. Get it online
By cable: plug ETH0 into your network. The box finds the internet by itself.
By Wi-Fi: power the box with no cable in ETH0. After about three minutes it opens its own Wi-Fi.
- Join the Setup Wi-Fi on the label with your phone, using the password on the label.
- A page opens by itself. If it does not, open
http://10.42.0.1. - Choose your Wi-Fi, type its password, Join.
The setup Wi-Fi closes once the box is online. If it comes back after a few minutes, the box could not join: try again.
2. Claim it
Sign in at app.kaynannexus.co.nz as an admin of your company.
Machine setup > IoT boxes, type the claim code, Add. The box is in your company from then on. Within a minute it shows Online.
From the box's card you can:
| On the card | What it does |
|---|---|
| Find devices | Lists what answers on the PLC network, and which machine controls answer (FANUC FOCAS, MTConnect, OPC UA, HEIDENHAIN, Mitsubishi). Add machine on a control starts the machine with its model and this box |
| Wi-Fi | Moves the box to another network. It keeps its old one if the new one does not work |
| Remote access | Lets your support reach the PLC network. Off until you turn it on. Over the VPN each device has its own address, shown as VPN IP next to it (the PLC at 192.168.0.12 is reached at an address such as 10.200.4.12), so two sites on the same network never mix up |
| Software, Update | Installs the latest Kaynan Nexus software on the box |
If the box stops checking in for ten minutes, your company's admins with alert emails on get an email, and another when it is back.
3. Connect a machine
- Machine setup, +, add the machine.
- On its Details tab, choose this box under IoT box, Save.
- On its Connection tab, open Siemens S7 or Modbus TCP under Connect through, and fill it in.
- Connect. The box sets it up within a minute and the values arrive on the Data tab.
List the values one per line, as name = address.
Siemens S7 (S7-1200 and S7-1500: rack 0, slot 1; S7-300: rack 0, slot 2). The PLC must allow PUT/GET, and data blocks you read must not use optimised access.
text
spindle_temp = DB1,REAL4
running = M0.1
parts = DB1,DINT8
alarm_word = DB55,WORD0Modbus TCP: the register as the device's manual gives it, counted from 0, then its type: int16, uint16, int32, uint32, float32 or bit with the bit number. *0.1 scales it; low-first swaps the words of a 32-bit value.
text
temperature = 0 int16 *0.1
running = 1 bit 0
parts = 10 uint32
pressure = 12 float32Connecting the machine again replaces what Connect set up before. The machine gets a new password each time, so anything else that sent as this machine stops.
Other controllers (Allen-Bradley, OPC UA, Fanuc, Omron, Mitsubishi) are read by the box too: ask your partner, or see Machines and controllers.